To calibrate the Output Sensor Press the Blue button in the mid lower part of the calibrations screen. This is usually done out at the dryer using the HMI Screen at the dryer. By pressing on the run screen in the area of the Output Sensor display you will advance to the Output Sensor Calibration Screen. Pressing the Blue button will begin a time sequence in which you should collect a sample of dry grain at the DM sampler box. A sample slide gate and chute is provided for collecting the sample.
Take multiple samples over the time period of 1 minute. Stir these sample in a collector and then Bench test the sample for a moisture reading. Then press the white rectangular box on the Output Sensor Calibration Screen for a drop-down keypad and enter the Tester value. Then Confirm Calibration on the screen with the rectangular Confirm Button located at the bottom of the screen. The sample calibration is normally completed on the PC located in the grain room near the tester. You can cancel calibration at any time by pressing the Cancel Calibration Button also located at the bottom of the screen.
The arrow in the upper right of the screen can return to the Run Screen at any time and then from the Run Screen you can return to finish the calibration process by pressing the Output Sensor area again on the run Screen.
Once you have confirmed the calibration you will need to use the same arrow to return to run screen.
It is recommended when testing a sample of grain to practice the following guidelines:
If sample is within ½% moisture of actual moisture displayed from sensor then make no calibration.
If sample is ½% to 1% moisture different than displayed from sensor then re-stir the sample in the bucket and test again and then make adjustment
If sample is greater than 1% difference than displayed from sensor then discard the sample and repeat sample collection again at the dryer.